RefriVerde


Industrial  Air Conditioning and Refrigeration   

 

 

Engineered Equipment manufactured according to end User requirements by RefriVerde Designs and Specifications

 

 

 

 

 

RVS Plate & Frame Chiller Packages.jpg

RVS Plates Cooler Package

 

 

 

RefriVerde  proposes innovative technologies for the Water Cooling and Ice Production for applications in Air Conditioning and Refrigeration Systems

 

Thermal Storage Systems (TES) with Liquid Ice (Fluid)

Vacuum Water Cooling and Ice Making using Water as Refrigerant  with Centrifugal Compressor

Cooling with the Absorption Cycle using Ammonia as Refrigerant

Air Cooled Ammonia Water Chillers , low refrigerant charge , suitable to integrate Refrigeration and Air Conditioning Systems in Supermarkets

Distributed Equipment (Plug-in) connected to a Water Loop where Chilled Water is used in the Condensers of Refrigeration Equipment

 

 

 

Buus Logo.jpg

 

 

Thermal Storage and Engineered Equipment

 

Ice banks for thermal accumulation

Evaporators for Ice Makers

Crystallizers , Lyophilization Chambers

Refrigerant  Recirculation Systems

 

 

 

 

 

Engineered  Equipment  with Bitzer or J&E Hall . . . according to requirements

 

RefriVerde  manufactures Special industrial-grade Refrigeration Equipment for Water Cooling and Ice Production in Commercial and Industrial Processes

 

Seawater chillers on fishing vessels with RSW system , Bitzer ammonia open screw compressor and titanium heat exchangers

RSW Systems for Fishing Vessels with standard tank from 36 to 500 M3

Power consumption for an Ammonia RSW is the lowest of all available refrigerants . Ammonia is the most environment-friendly refrigerant available

► Variable frequency drive for Compressor and Pumps on demand

Bitzer compressor with Overhaul intervals of 100,000 hours

Continuously variable capacity control 10-100% on OSKA9500 series

The Compressor is not contaminated in the event of burning the Motor

Coupling and Coupling Housing for the aligned of the Motor

Seawater-cooled Oil Cooler for increased efficiency

Titanium tubes and tube sheets in all heat exchangers .Tube joints are expanded and welded

PLC controller offering automatic operation and monitoring of parameters

See Data with 2-Pole Electric Motor (60 Hz) in the following link

NH3 Seawater Chillers , RSW Systems , Bitzer Open Screw Compressor , Rev.250901

 

Water Chillers with HFC-134A , 407C and NH3

► A single Screw Compressor, Variable Speed

► Water Chillers with low Ammonia load , Air Condensation

Open Compressor for ease of maintenance and greater reliability

Coupling Housing for the aligned of the Motor

Electrical Motor IP 55 , FS 1.15 , Premium IE 3 , 3600 RPM (60 Hz)

See Data with 2-Pole Electric Motor (60 Hz) in the following link

Water Chillers , 134A & 407C with Bitzer Compressor

 

Water Chillers in Natural Gas Cogeneration Packages

Natural Gas or Biomethane Engines , a wise choice when electricity is expensive or difficult to access

Variable Speed Motor according to Water Temperature

The best option when additional Hot Water or low pressure steam is required , such as in Hospitals and Hotels

► 3-Stage Heat Recovery (Condenser + Engine Cooling + Exhaust Gases) for Hot Water or Steam supply

See CCHP Cogeneration Package Data in the following link

Water Chillers in CCHP Cogeneration Packages with Natural Gas , Bitzer Open Screw Compressor

 

An additional system can be considered for heat recovery to produce energy in an Organic Rankine Cycle (ORC) with Bitzer Expander using HFC-245fa or 134a . . .

 

 

 

 

 